Power amplifier

433~480MHz, Gain51dB, Psat45dBm, SMA

  • DPA9-433-480-2111
  • China
  • One Year
  • +86-19938031308
  • sales@com-mw.com, cynthia@com-mw.com
  • 3-1-2306, No.37 Jiancai Road, Chenghua Zone, Chengdu
  • For qty details, please search in spot products of dianzibuy. Any changes to the contents are not notified. Please confirm again before ordering.
  • No restrictions on export to any country
  • RoHS: no(Customization Needed for ROHS Compliance)
  • The product must not be used for illegal purposes. Any losses caused by illegal use shall be borne by the customer.

Product Details

Product features

Suitable for fields such as drone interference and aging testing.

Tech specifications

ParametersMinTypicalMaxUnits
Frequency433~480MHz
Gain51dB
Gain flatness±1dB
Input VSWR1.4
Psat444546dBm
Max input power10dBm
ALC control range10dB
Gain Adjustment Range25dBc

Environmental

ConnectorSMA-K
Temperature protection+85 ℃ over temperature alarm and shutdown, 65 ℃ open
Transmission and control interfaceCMOS3.3V
Ripple≤2.5dB
Impedance50Ω
Working voltage+28V
Working current4500mA
Operation Temp.-40~+55℃ Design assurance
Gain adjustment accuracyAttenuation of 10dB: ≤ ± 1dB; Attenuation of 20dB: ≤ ± 1dB; Attenuation of 25dB: ≤ ± 1.5dB

Typical test data

F (MHz)Gain(dB)Pout(SAT)Ids(A)IdQ(mA)
42048.9344.552.26400
43049.6745.312.6400
44050.7746.213.06400
45051.7447.333.48400
46052.3847.083.26400
47052.344.852.82400
48051.4344.532.96400

Reference picture

Configuration

Monitoring function

RS485 interface

1) Settings: switch, gain;

2) Query: Module status (including amplifier status, over power alarm, over temperature alarm), amplifier temperature, amplifier ATT value, detected forward power;

3) Overpower alarm: If the power exceeds the maximum output power by+2dB, an alarm will be triggered;

4) Over temperature alarm: It is recommended to set the threshold to+85 ℃. If the temperature exceeds+85 ℃, an alarm should be triggered and the power amplifier should be turned off. When+65 ℃ is reached, the power amplifier should be turned on;

5) Temperature detection of power amplifier: The detection range is required to include but not limited to -25 ℃ to+85 ℃, and the detection accuracy is required to be ± 3 ℃;

6) Forward power detection: The detection range should be greater than 20dB, and the detection accuracy should be less than ± 1dB;

Note

Store in an environment with a humidity of less than 25%, pay attention to dust and anti-static measures, and consider amplifier heat dissipation during installation.